NVELOP Documents

Find all the NVELOP documentation you need, from sell sheets, details and technical specs to brochures and other literature.

Specifications and Letters

Details

Complete Detail Packet

Complete NVELOP Detail Packet

Introduction

Detail 1.0 - Continuous air & vapor barrier detail guide

Detail 1.1 - NVELOP roof assembly options

Detail 1.2 - Roof vapor retarder

Detail 1.3 - Minimum insulation R-values

Wall Assembly Types

Detail 2.1 - Stud wall cavity & exterior insulation

Detail 2.2 - CMU or concrete wall with exterior insulation

Detail 2.3 - Stud wall with stud-cavity insulation only

Detail 2.4 - CMU or concrete wall without wall insulation

Detail 2.5 - Stud wall with non-nailable exterior insulating sheathing

Detail 2.6 - Stud wall with nailable exterior insulating sheathing

Detail 2.7 - Stud wall with insulated membrane and WRB on insulation

Detail 2.8 - CMU or concrete wall with insulated membrane and WRB on insulation

Detail 2.9 - Stud wall with un-insulated membrane on exterior side

Detail 2.10 - CMU or concrete wall with un-insulated membrane on exterior side

Detail 2.11 - CMU or concrete wall with insulated membrane on interior side

Detail 2.12 - CMU or concrete wall with un-insulated membrane on interior side

Roof-to-wall Tie-in Details

Detail 3.1 - Tie-in details for parapet or low roof edges

Detail 3.2 - Tie-in Sure-Seal EPDM with CCW 705 membrane

Detail 3.3 - Tie-in Sure-Weld TPO with CCW 705 membrane

Detail 3.4 - Tie-in Sure-Flex PVC with CCW 705 membrane

Detail 3.5 - Tie-in Sure-Seal EPDM with Barriseal or Barritech

Detail 3.6 - Tie-in Sure-Weld TPO with Barriseal or Barritech

Detail 3.7 -Tie-in Sure-Flex PVC with Barriseal or Barritech

Detail 3.8 - Roof vapor barrier tie-in with wall membrane barrier

Detail 3.9 - Roof vapor barrier tie-in with wall fluid-applied barrier

Detail 3.10 -Low roof to upper story wall tie-in

Universal Details

Detail 4.1 - Shelf angle - self-adhered AVB flashing

Detail 4.2 - Shelf angle - fluid-applied AVB flashing

Detail 4.3 - Window head and sill flashing - option A

Detail 4.4 - Window jamb flashing - option B

Detail 4.5 - Window head and sill flashing - option B

Detail 4.6 - Window jamb - option B

Detail 4.7 - Self-adhering AVB - sheathing joints and ties

Detail 4.8 - Fluid-applied AVB - sheathing joints and ties

Detail 4.9 - Stud wall joint greater than one inch (25mm)

Detail 4.10 - Conduit penetration flashing

Below Grade Details

Detail 5.1 - Floor slab - waterproofing and vapor proofing

Detail 5.2 - Positive side waterproofing - wall and slab tie-in using MiraPLY

Detail 5.3 - Positive side waterproofing - MiraPLY tie-in splice

Detail 5.4 - Negative side waterproofing - wall and slab MiraPLY tie-in

Detail 5.5 - Negative side waterproofing - MiraPLY splice options

Detail 5.6 - Slab on grade

Detail 5.7 - Ground floor - slab-on-grade with foundation wall

Detail 5.8 - Basement - foundation and floor wall tie-in

Detail 5.9 - Wall flashing at top of foundation

Detail 5.10 - Negative side waterproofing - MiraDRAIN splice

Detail A - CCM building envelope table of contents

See Warranty Details

Protect your building envelope with the industry’s only single-source tie-in warranty.

See Options

Order Literature

Order NVELOP literature including brochures, warranty and spec sell sheets, details, and program binders.

Order Literature

Get in Touch

Discover how we can customize a solution to meet your building envelope needs.

Learn More